Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44.199
Filtrar
1.
Opt Lett ; 49(7): 1741-1744, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38560851

RESUMO

Speckle-correlation optical scattering imaging (SCOSI) has shown the potential for non-invasive biomedical diagnostic applications, which directly utilizes the scattering patterns to reconstruct the deep and non-line-of-sight objects. However, the course of the translation of this technique to preclinical biomedical imaging applications has been postponed by the following two facts: 1) the field of view of SCOSI was significantly limited by the optical memory effect, and 2) the molecular-tagged functional imaging of the biological tissues remains largely unexplored. In this work, a proof-of-concept design of the first-generation widefield functional SCOSI (WF-SCOSI) system was presented for simultaneously achieving mesoscopic mapping of fluid morphology and flow rate, which was realized by implementing the concepts of scanning synthesis and fluorescence scattering flowmetry. The ex vivo imaging results of the fluorescence-labeled large-scale blood vessel network phantom underneath the strong scatters demonstrated the effectiveness of WF-SCOSI toward non-invasive hemodynamic imaging applications.


Assuntos
Diagnóstico por Imagem , Hemodinâmica , Imagens de Fantasmas , Reologia , Desenho de Equipamento , Imagem Óptica/métodos
2.
Sci Rep ; 14(1): 8253, 2024 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589478

RESUMO

This work presents a deep learning approach for rapid and accurate muscle water T2 with subject-specific fat T2 calibration using multi-spin-echo acquisitions. This method addresses the computational limitations of conventional bi-component Extended Phase Graph fitting methods (nonlinear-least-squares and dictionary-based) by leveraging fully connected neural networks for fast processing with minimal computational resources. We validated the approach through in vivo experiments using two different MRI vendors. The results showed strong agreement of our deep learning approach with reference methods, summarized by Lin's concordance correlation coefficients ranging from 0.89 to 0.97. Further, the deep learning method achieved a significant computational time improvement, processing data 116 and 33 times faster than the nonlinear least squares and dictionary methods, respectively. In conclusion, the proposed approach demonstrated significant time and resource efficiency improvements over conventional methods while maintaining similar accuracy. This methodology makes the processing of water T2 data faster and easier for the user and will facilitate the utilization of the use of a quantitative water T2 map of muscle in clinical and research studies.


Assuntos
Algoritmos , Aprendizado Profundo , Água , Calibragem , Imageamento por Ressonância Magnética/métodos , Músculos/diagnóstico por imagem , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos , Encéfalo
3.
Med Image Anal ; 94: 103158, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38569379

RESUMO

Magnetic resonance (MR) images collected in 2D clinical protocols typically have large inter-slice spacing, resulting in high in-plane resolution and reduced through-plane resolution. Super-resolution technique can enhance the through-plane resolution of MR images to facilitate downstream visualization and computer-aided diagnosis. However, most existing works train the super-resolution network at a fixed scaling factor, which is not friendly to clinical scenes of varying inter-slice spacing in MR scanning. Inspired by the recent progress in implicit neural representation, we propose a Spatial Attention-based Implicit Neural Representation (SA-INR) network for arbitrary reduction of MR inter-slice spacing. The SA-INR aims to represent an MR image as a continuous implicit function of 3D coordinates. In this way, the SA-INR can reconstruct the MR image with arbitrary inter-slice spacing by continuously sampling the coordinates in 3D space. In particular, a local-aware spatial attention operation is introduced to model nearby voxels and their affinity more accurately in a larger receptive field. Meanwhile, to improve the computational efficiency, a gradient-guided gating mask is proposed for applying the local-aware spatial attention to selected areas only. We evaluate our method on the public HCP-1200 dataset and the clinical knee MR dataset to demonstrate its superiority over other existing methods.


Assuntos
Diagnóstico por Computador , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Redes Neurais de Computação , Articulação do Joelho , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos
4.
J Comput Aided Mol Des ; 38(1): 17, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38570405

RESUMO

The development of peptides for therapeutic targets or biomarkers for disease diagnosis is a challenging task in protein engineering. Current approaches are tedious, often time-consuming and require complex laboratory data due to the vast search spaces that need to be considered. In silico methods can accelerate research and substantially reduce costs. Evolutionary algorithms are a promising approach for exploring large search spaces and can facilitate the discovery of new peptides. This study presents the development and use of a new variant of the genetic-programming-based POET algorithm, called POET Regex , where individuals are represented by a list of regular expressions. This algorithm was trained on a small curated dataset and employed to generate new peptides improving the sensitivity of peptides in magnetic resonance imaging with chemical exchange saturation transfer (CEST). The resulting model achieves a performance gain of 20% over the initial POET models and is able to predict a candidate peptide with a 58% performance increase compared to the gold-standard peptide. By combining the power of genetic programming with the flexibility of regular expressions, new peptide targets were identified that improve the sensitivity of detection by CEST. This approach provides a promising research direction for the efficient identification of peptides with therapeutic or diagnostic potential.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Humanos , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos , Peptídeos
5.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 156-159, 2024 Mar 30.
Artigo em Chinês | MEDLINE | ID: mdl-38605614

RESUMO

Objective: The distribution of the photon energy spectrum in isocenter plane of the medical linear accelerator and the influence of secondary collimator on the photon energy spectrum are studied. Methods Use the BEAMnrc program to simulate the transmission of the 6 MeV electrons and photons in 5 cm×5 cm,10 cm×10 cm,15 cm×15 cm and 20 cm×20 cm fields in treatment head of the medical linear accelerator, where a phase space file was set up at the isocenter plane to record the particle information passing through this plane. The BEAMdp program is used to analyze the phase space file, in order to obtain the distribution of the photon energy spectrum in isocenter plane and the influence of secondary collimator on the photon energy spectrum. Results: By analyzing the photon energy spectrum of a medical linear accelerator with a nominal energy of 6 MV, it is found that the secondary collimator has little effect on the photon energy spectrum; different fields have different photon energy spectrum distributions; the photon energy spectrum in different central regions of the same field have the same normalized distribution. Conclusion: In the dose calculation of radiation therapy, the influence of photon energy spectrum should be carefully considered.


Assuntos
Fótons , Planejamento da Radioterapia Assistida por Computador , Método de Monte Carlo , Fótons/uso terapêutico , Aceleradores de Partículas , Imagens de Fantasmas , Dosagem Radioterapêutica
6.
PLoS One ; 19(4): e0296357, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38578749

RESUMO

OBJECTIVE: Quantitative values derived from PET brain images are of high interest for neuroscientific applications. Insufficient DT correction (DTC) can lead to a systematic bias of the output parameters obtained by a detailed analysis of the time activity curves (TACs). The DTC method currently used for the Siemens 3T MR BrainPET insert is global, i.e., differences in DT losses between detector blocks are not considered, leading to inaccurate DTC and, consequently, to inaccurate measurements masked by a bias. However, following careful evaluation with phantom measurements, a new block-pairwise DTC method has demonstrated a higher degree of accuracy compared to the global DTC method. APPROACH: Differences between the global and the block-pairwise DTC method were studied in this work by applying several radioactive tracers. We evaluated the impact on [11C]ABP688, O-(2-[18F]fluoroethyl)-L-tyrosine (FET), and [15O]H2O TACs. RESULTS: For [11C]ABP688, a relevant bias of between -0.0034 and -0.0053 ml/ (cm3 • min) was found in all studied brain regions for the volume of distribution (VT) when using the current global DTC method. For [18F]FET-PET, differences of up to 10% were observed in the tumor-to-brain ratio (TBRmax), these differences depend on the radial distance of the maximum from the PET isocenter. For [15O]H2O, differences between +4% and -7% were observed in the GM region. Average biases of -4.58%, -3.2%, and -1.2% for the regional cerebral blood flow (CBF (K1)), the rate constant k2, and the volume of distribution VT were observed, respectively. Conversely, in the white matter region, average biases of -4.9%, -7.0%, and 3.8% were observed for CBF (K1), k2, and VT, respectively. CONCLUSION: The bias introduced by the global DTC method leads to an overestimation in the studied quantitative parameters for all applications compared to the block-pairwise method. SIGNIFICANCE: The observed differences between the two DTC methods are particularly relevant for research applications in neuroscientific studies as they affect the accuracy of quantitative Brain PET images.


Assuntos
Encéfalo , Oximas , Tomografia por Emissão de Pósitrons , Piridinas , Tomografia por Emissão de Pósitrons/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Imagens de Fantasmas , Cabeça , Imageamento por Ressonância Magnética
7.
BMC Oral Health ; 24(1): 420, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580965

RESUMO

BACKGROUND: Interstitial brachytherapy is a form of intensive local irradiation that facilitates the effective protection of surrounding structures and the preservation of organ functions, resulting in a favourable therapeutic response. As surgical robots can perform needle placement with a high level of accuracy, our team developed a fully automatic radioactive seed placement robot, and this study aimed to evaluate the accuracy and feasibility of fully automatic radioactive seed placement for the treatment of tumours in the skull base. METHODS: A fully automatic radioactive seed placement robot was established, and 4 phantoms of skull base tumours were built for experimental validation. All the phantoms were subjected to computed tomography (CT) scans. Then, the CT data were imported into the Remebot software to design the preoperative seed placement plan. After the phantoms were fixed in place, navigation registration of the Remebot was carried out, and the automatic seed placement device was controlled to complete the needle insertion and particle placement operations. After all of the seeds were implanted in the 4 phantoms, postoperative image scanning was performed, and the results were verified via image fusion. RESULTS: A total of 120 seeds were implanted in 4 phantoms. The average error of seed placement was (2.51 ± 1.44) mm. CONCLUSION: This study presents an innovative, fully automated radioactive particle implantation system utilizing the Remebot device, which can successfully complete automated localization, needle insertion, and radioactive particle implantation procedures for skull base tumours. The phantom experiments showed the robotic system to be reliable, stable, efficient and safe. However, further research on the needle-soft tissue interaction and deformation mechanism of needle puncture is still needed.


Assuntos
Implantes Dentários , Robótica , Neoplasias da Base do Crânio , Humanos , Neoplasias da Base do Crânio/diagnóstico por imagem , Neoplasias da Base do Crânio/radioterapia , Neoplasias da Base do Crânio/cirurgia , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
8.
Eur Radiol Exp ; 8(1): 49, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38622388

RESUMO

BACKGROUND: Automatic exposure control (AEC) plays a crucial role in mammography by determining the exposure conditions needed to achieve specific image quality based on the absorption characteristics of compressed breasts. This study aimed to characterize the behavior of AEC for digital mammography (DM), digital breast tomosynthesis (DBT), and low-energy (LE) and high-energy (HE) acquisitions used in contrast-enhanced mammography (CEM) for three mammography systems from two manufacturers. METHODS: Using phantoms simulating various breast thicknesses, 363 studies were acquired using all available AEC modes 165 DM, 132 DBT, and 66 LE-CEM and HE-CEM. AEC behaviors were compared across systems and modalities to assess the impact of different technical components and manufacturers' strategies on the resulting mean glandular doses (MGDs) and image quality metrics such as contrast-to-noise ratio (CNR). RESULTS: For all systems and modalities, AEC increased MGD for increasing phantom thicknesses and decreased CNR. The median MGD values (interquartile ranges) were 1.135 mGy (0.772-1.668) for DM, 1.257 mGy (0.971-1.863) for DBT, 1.280 mGy (0.937-1.878) for LE-CEM, and 0.630 mGy (0.397-0.713) for HE-CEM. Medians CNRs were 14.2 (7.8-20.2) for DM, 4.91 (2.58-7.20) for a single projection in DBT, 11.9 (8.0-18.2) for LE-CEM, and 5.2 (3.6-9.2) for HE-CEM. AECs showed high repeatability, with variations lower than 5% for all modes in DM, DBT, and CEM. CONCLUSIONS: The study revealed substantial differences in AEC behavior between systems, modalities, and AEC modes, influenced by technical components and manufacturers' strategies, with potential implications in radiation dose and image quality in clinical settings. RELEVANCE STATEMENT: The study emphasized the central role of automatic exposure control in DM, DBT, and CEM acquisitions and the great variability in dose and image quality among manufacturers and between modalities. Caution is needed when generalizing conclusions about differences across mammography modalities. KEY POINTS: • AEC plays a crucial role in DM, DBT, and CEM. • AEC determines the "optimal" exposure conditions needed to achieve specific image quality. • The study revealed substantial differences in AEC behavior, influenced by differences in technical components and strategies.


Assuntos
Mamografia , Intensificação de Imagem Radiográfica , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Mamografia/métodos , Imagens de Fantasmas
9.
J Biomed Opt ; 29(4): 046008, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38659998

RESUMO

Significance: Optical imaging is a non-invasive imaging technology that utilizes near-infrared light, allows for the image reconstruction of optical properties like diffuse and absorption coefficients within the tissue. A recent trend is to use signal processing techniques or new light sources and expanding its application. Aim: We aim to develop the reflective optical imaging using the chaotic correlation technology with chaotic laser and optimize the quality and spatial resolution of reflective optical imaging. Approach: Scattering medium was measured using reflective configuration in different inhomogeneous regions to evaluate the performance of the imaging system. The accuracy of the recovered optical properties was investigated. The reconstruction errors of absorption coefficients and geometric centers were analyzed, and the feature metrics of the reconstructed images were evaluated. Results: We showed how chaotic correlation technology can be utilized for information extraction and image reconstruction. This means that a higher signal-to-noise ratio and image reconstruction of inhomogeneous phantoms under different scenarios successfully were achieved. Conclusions: This work highlights that the peak values of correlation of chaotic exhibit smaller reconstruction error and better reconstruction performance in optical imaging compared with reflective optical imaging with the continuous wave laser.


Assuntos
Processamento de Imagem Assistida por Computador , Lasers , Imagem Óptica , Imagens de Fantasmas , Espalhamento de Radiação , Imagem Óptica/métodos , Processamento de Imagem Assistida por Computador/métodos , Razão Sinal-Ruído , Dinâmica não Linear , Algoritmos , Desenho de Equipamento
10.
Sci Rep ; 14(1): 9373, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653993

RESUMO

To facilitate a prospective estimation of the effective dose of an CT scan prior to the actual scanning in order to use sophisticated patient risk minimizing methods, a prospective spatial dose estimation and the known anatomical structures are required. To this end, a CT reconstruction method is required to reconstruct CT volumes from as few projections as possible, i.e. by using the topograms, with anatomical structures as correct as possible. In this work, an optimized CT reconstruction model based on a generative adversarial network (GAN) is proposed. The GAN is trained to reconstruct 3D volumes from an anterior-posterior and a lateral CT projection. To enhance anatomical structures, a pre-trained organ segmentation network and the 3D perceptual loss are applied during the training phase, so that the model can then generate both organ-enhanced CT volume and organ segmentation masks. The proposed method can reconstruct CT volumes with PSNR of 26.49, RMSE of 196.17, and SSIM of 0.64, compared to 26.21, 201.55 and 0.63 using the baseline method. In terms of the anatomical structure, the proposed method effectively enhances the organ shapes and boundaries and allows for a straight-forward identification of the relevant anatomical structures. We note that conventional reconstruction metrics fail to indicate the enhancement of anatomical structures. In addition to such metrics, the evaluation is expanded with assessing the organ segmentation performance. The average organ dice of the proposed method is 0.71 compared with 0.63 for the baseline model, indicating the enhancement of anatomical structures.


Assuntos
Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Doses de Radiação , Imagens de Fantasmas , Algoritmos , Estudos Prospectivos
11.
Biomed Phys Eng Express ; 10(3)2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38604150

RESUMO

We have previously reported the design of a portable109Cd x-ray fluorescence (XRF) system to measure iron levels in the skin of patients with either iron overload disease, such as thalassemia, or iron deficiency disease, such as anemia. In phantom studies, the system was found to have a detection limit of 1.35µg Fe per g of tissue for a dose of 1.1 mSv. However, the system must provide accurate as well as precise measurements of iron levels in the skin in order to be suitable for human studies. The accuracy of the system has been explored using several methods. First, the iron concentrations of ten pigskin samples were assessed using both the portable XRF system and ICP-MS, and the results were compared. Overall, it was found that XRF and ICP-MS reported average values for iron in skin that were comparable to within uncertainties. The mean difference between the two methodologies was not significant, 2.5 ± 4.6µg Fe per g. On this basis, the system could be considered accurate. However, ICP-MS measurements reported a wider range of values than XRF, with two individual samples having ICP-MS results that were significantly elevated (p < 0.05) compared to XRF. SynchrotronµXRF maps of iron levels in pigskin were acquired on the BioXAS beam line of the Canadian Light Source. TheµXRF maps indicated two important features in the distribution of iron in pigskin. First, there were small areas of high iron concentration in the pigskin samples, that were predominantly located in the dermis and hypodermis at depths greater than 0.5 mm. Monte Carlo modelling using the EGS 5 code determined that if these iron 'hot spots' were located towards the back of the skin at depths greater than 0.5 mm, they would not be observed by XRF, but would be measured by ICP-MS. These results support a hypothesis that iron levels in the two samples that reported significantly elevated ICP-MS results compared to XRF may have had small blood vessels at the back of the skin. Second, the synchrotronµXRF maps also showed a narrow (approximately 100µm thick) layer of elevated iron at the surface of the skin. Monte Carlo models determined that, as expected, the XRF system was most sensitive to these skin layers. However, the simulations found that the XRF system, when calibrated against homogenous water-based phantoms, was found to accurately measure average iron levels in the skin of normal pigs despite the greater sensitivity to the surface layer. The Monte Carlo results further indicated that with highly elevated skin surface iron levels, the XRF system would not provide a good estimate of average skin iron levels. The XRF estimate could, with correction factors, provide a good estimate of the iron levels in the surface layers of skin. There is limited data on iron distribution in skin, especially under conditions of disease. If iron levels are elevated at the skin surface by diseases including thalassemia and hemochromatosis, this XRF device may prove to be an accurate clinical tool. However, further data are required on skin iron distributions in healthy and iron overload disease before this system can be verified to provide accurate measurements.


Assuntos
Ferro , Pele , Espectrometria por Raios X , Ferro/análise , Pele/metabolismo , Animais , Suínos , Espectrometria por Raios X/métodos , Espectrometria por Raios X/instrumentação , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Espectrometria de Massas/métodos , Cádmio/análise
12.
Med Eng Phys ; 126: 104144, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38621846

RESUMO

The present study adopts a smartphone-based approach for the experimental characterization of coronary flows. Technically, Particle Tracking Velocimetry (PTV) measurements were performed using a smartphone camera and a low-power continuous wave laser in realistic healthy and stenosed phantoms of left anterior descending artery with inflow Reynolds numbers approximately ranging from 20 to 200. A Lagrangian-Eulerian mapping was performed to convert Lagrangian PTV velocity data to a Eulerian grid. Eulerian velocity and vorticity data obtained from smartphone-based PTV measurements were compared with Particle Image Velocimetry (PIV) measurements performed with a smartphone-based setup and with a conventional setup based on a high-power double-pulsed laser and a CMOS camera. Smartphone-based PTV and PIV velocity flow fields substantially agreed with conventional PIV measurements, with the former characterized by lower average percentage differences than the latter. Discrepancies emerged at high flow regimes, especially at the stenosis throat, due to particle image blur generated by smartphone camera shutter speed and image acquisition frequency. In conclusion, the present findings demonstrate the feasibility of PTV measurements using a smartphone camera and a low-power light source for the in vitro characterization of cardiovascular flows for research, industrial and educational purposes, with advantages in terms of costs, safety and usability.


Assuntos
Fenômenos Fisiológicos Cardiovasculares , Smartphone , Reologia/métodos , Velocidade do Fluxo Sanguíneo , Imagens de Fantasmas
13.
Medicine (Baltimore) ; 103(15): e37748, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38608106

RESUMO

We aimed to investigate the accuracy of proton density fat fraction (PDFF) measurement of the lumbar vertebral bone marrow using chemical shift-encoded magnetic resonance imaging (CSE-MRI) with compressed sensing combined with parallel imaging (CSPI). This study recruited a commercially available phantom, and 43 patients. Fully sampled data without CSPI and under-sampled data with CSPI acceleration factors of 2.4, 3.6, and 4.8 were acquired using a 1.5T imaging system. The relationships between PDFF measurements obtained with the no-CSPI acquisition and those obtained with each CSPI acquisition were assessed using Pearson correlation coefficient (r), linear regression analyses, and Bland-Altman analysis. The intra- and inter-observer variabilities of the PDFF measurements were evaluated using the intraclass correlation coefficient. PDFF measurements obtained with all acquisitions showed a significant correlation and strong agreement with the reference PDFF measurement of the phantom. PDFF measurements obtained using CSE-MRI with and without CSPI were positively correlated (all acquisitions: r = 0.99; P < .001). The mean bias was -0.31% to -0.17% with 95% limits of agreement within ±2.02%. The intra- and inter-observer agreements were excellent (intraclass correlation coefficient: 0.988 and 0.981, respectively). A strong agreement and positive correlation were observed between the PDFF measurements obtained using CSE-MRI with and without CSPI. PDFF measurement of the lumbar vertebral bone marrow using CSE-MRI with CSPI can be acquired with a maximum reduction of approximately 75% in the acquisition time compared with a fully sampled acquisition.


Assuntos
Medula Óssea , Prótons , Humanos , Medula Óssea/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagens de Fantasmas
14.
Radiat Oncol ; 19(1): 40, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509543

RESUMO

PURPOSE: To assess a large panel of MR compatible detectors on the full range of measurements required for a 0.35 T MR-linac commissioning by using a specific statistical method represented as a continuum of comparison with the Monte Carlo (MC) TPS calculations. This study also describes the commissioning tests and the secondary MC dose calculation validation. MATERIAL AND METHODS: Plans were created on the Viewray TPS to generate MC reference data. Absolute dose points, PDD, profiles and output factors were extracted and compared to measurements performed with ten different detectors: PTW 31010, 31021, 31022, Markus 34045 and Exradin A28 MR ionization chambers, SN Edge shielded diode, PTW 60019 microdiamond, PTW 60023 unshielded diode, EBT3 radiochromic films and LiF µcubes. Three commissioning steps consisted in comparison between calculated and measured dose: the beam model validation, the output calibration verification in four different phantoms and the commissioning tests recommended by the IAEA-TECDOC-1583. MAIN RESULTS: The symmetry for the high resolution detectors was higher than the TPS data of about 1%. The angular responses of the PTW 60023 and the SN Edge were - 6.6 and - 11.9% compared to the PTW 31010 at 60°. The X/Y-left and the Y-right penumbras measured by the high resolution detectors were in good agreement with the TPS values except for the PTW 60023 for large field sizes. For the 0.84 × 0.83 cm2 field size, the mean deviation to the TPS of the uncorrected OF was - 1.7 ± 1.6% against - 4.0 ± 0.6% for the corrected OF whereas we found - 4.8 ± 0.8% for passive dosimeters. The mean absolute dose deviations to the TPS in different phantoms were 0 ± 0.4%, - 1.2 ± 0.6% and 0.5 ± 1.1% for the PTW 31010, PTW 31021 and Exradin A28 MR respectively. CONCLUSIONS: The magnetic field effects on the measurements are considerably reduced at low magnetic field. The PTW 31010 ionization chamber can be used with confidence in different phantoms for commissioning and QA tests requiring absolute dose verifications. For relative measurements, the PTW 60019 presented the best agreement for the full range of field size. For the profile assessment, shielded diodes had a behaviour similar to the PTW 60019 and 60023 while the ionization chambers were the most suitable detectors for the symmetry. The output correction factors published by the IAEA TRS 483 seem to be applicable at low magnetic field pending the publication of new MR specific values.


Assuntos
Aceleradores de Partículas , Radiometria , Humanos , Radiometria/métodos , Método de Monte Carlo , Imagens de Fantasmas , Calibragem
15.
Health Phys ; 126(5): 292-295, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38526247

RESUMO

ABSTRACT: The Human Monitoring Laboratory, Health Canada (HML), has used a 3D printer to re-engineer its Lawrence Livermore National Laboratory (LLNL) foam lung sets (manufactured by Radiology Support Devices, Inc., Long Beach, CA). The foam sets are currently the HML standard for calibrating and performance testing lung-counting systems in Canada. This paper describes the process of creating and validating new 3D-printed lung sets modeled from one of the HML's existing RSD foam sets. The existing sets were custom made, making them costly and difficult to obtain or replace. Also, after many years of use, the HML has found that they are prone to wear and tear. When used with planar inserts containing various isotopes, the blank sets can become contaminated and are difficult to clean. Using 3D printing, the HML has created new blank lung sets that are nearly identical copies of the originals and are inexpensive and easily manufactured. Measurements using natural uranium (Nat U), 241Am, and 152Eu planar lung inserts were performed to compare obtained efficiencies at a wide range of energies using the original RSD foam sets and the 3D-printed ones. Both the foam and the 3D-printed lung sets were counted using the LLNL chest phantom positioned in the same counting geometry in the lung counting system. Biases, all below 15%, were obtained between the foam and the 3D-printed sets for energies above 40 KeV. Based on these results, as well as cost benefits and ease of use, the HML has decided to replace its original RSD foam lung set with the 3D-printed version for its lung performance testing program.


Assuntos
Amerício , Impressão Tridimensional , Humanos , Imagens de Fantasmas , Canadá
16.
J Biomed Opt ; 29(Suppl 1): S11528, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38505737

RESUMO

Significance: Endocavity ultrasound (US) imaging is a frequently employed diagnostic technique in gynecology and urology for the assessment of male and female genital diseases that present challenges for conventional transabdominal imaging. The integration of photoacoustic (PA) imaging with clinical US imaging has displayed promising outcomes in clinical research. Nonetheless, its application has been constrained due to size limitations, restricting it to spatially confined locations such as vaginal or rectal canals. Aim: This study presents the development of a video-rate (20 Hz) endocavity PA/harmonic US imaging (EPAUSI) system. Approach: The approach incorporates a commercially available endocavity US probe with a miniaturized laser delivery unit, comprised of a single large-core fiber and a line beamshaping engineered diffuser. The system facilitates real-time image display and subsequent processing, including angular energy density correction and spectral unmixing, in offline mode. Results: The spatial resolutions of the concurrently acquired PA and harmonic US images were measured at 318 µm and 291 µm in the radial direction, respectively, and 1.22 deg and 1.50 deg in the angular direction, respectively. Furthermore, the system demonstrated its capability in multispectral PA imaging by successfully distinguishing two clinical dyes in a tissue-mimicking phantom. Its rapid temporal resolution enabled the capture of kinetic dye perfusion into an ex vivo porcine ovary through the depth of porcine uterine tissue. EPAUSI proved its clinical viability by detecting pulsating hemodynamics in the male rat's prostate in vivo and accurately classifying human blood vessels into arteries and veins based on sO2 measurements. Conclusions: Our proposed EPAUSI system holds the potential to unveil previously overlooked indicators of vascular alterations in genital cancers or endometriosis, addressing pressing requirements in the fields of gynecology and urology.


Assuntos
Diagnóstico por Imagem , Técnicas Fotoacústicas , Suínos , Animais , Masculino , Feminino , Humanos , Ultrassonografia/métodos , Imagens de Fantasmas , Análise Espectral , Corantes , Técnicas Fotoacústicas/métodos
17.
Biosensors (Basel) ; 14(3)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38534256

RESUMO

A proof-of-concept of a microwave imaging system for the fast detection of abdominal aortic aneurysms is shown. This experimental technology seeks to overcome the factors hampering the fast screening for these aneurysms with the usual equipment, such as high cost, long-time operation or hazardous exposure to chemical substances. The hardware system is composed of 16 twin antennas mastered by a microcontroller through a switching network, which connects the antennas to the measurement instrument for sequential measurement. The software system is run by a computer, mastering the whole system, automatizing the measurement process and running the signal processing and medical image generation algorithms. Two image generation algorithms are tested: Delay-and-Sum (DAS) and Improved Delay-and-Sum (IDAS). Own-modified versions of these algorithms adapted to the requirements of our system are proposed. The system is carefully calibrated and fine-tuned with known objects placed at known distances. An experimental proof-of-concept is shown with a human torso phantom, including an aorta phantom and an aneurysm phantom placed in different positions. The results show good imaging capabilities with the potential for detecting and locating possible abdominal aortic aneurysms and reporting acceptable errors.


Assuntos
Aneurisma da Aorta Abdominal , Imageamento de Micro-Ondas , Humanos , Aneurisma da Aorta Abdominal/diagnóstico , Software , Algoritmos , Imagens de Fantasmas
18.
Phys Med Biol ; 69(7)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38471178

RESUMO

Objective.Ion computed tomography (iCT) is an imaging modality for the direct determination of the relative stopping power (RSP) distribution within a patient's body. Usually, this is done by estimating the path and energy loss of ions traversing the scanned volume utilising a tracking system and a separate residual energy detector. This study, on the other hand, introduces the first experimental study of a novel iCT approach based on time-of-flight (TOF) measurements, the so-called Sandwich TOF-iCT concept, which in contrast to any other iCT systems, does not require a residual energy detector for the RSP determination.Approach.A small Sandwich TOF-iCT demonstrator was built based on low gain avalanche diodes (LGADs), which are 4D-tracking detectors that allow to simultaneously measure the particle position and time-of-arrival with a precision better than 100µm and 100 ps, respectively. Using this demonstrator, the material and energy-dependent TOF was measured for several homogeneous PMMA slabs in order to calibrate the acquired TOF against the corresponding water equivalent thickness (WET). With this calibration, two proton radiographs (pRads) of a small aluminium stair phantom were recorded at MedAustron using 83 MeV and 100.4 MeV protons.Main results.Due to the simplified WET calibration models used in this very first experimental study of this novel approach, the difference between the measured and theoretical WET ranged between 37.09% and 51.12%. Nevertheless, the first TOF-based pRad was successfully recorded showing that LGADs are suitable detector candidates for Sandwich TOF-iCT.Significance.While the system parameters and WET estimation algorithms require further optimization, this work was an important first step to realize Sandwich TOF-iCT. Due to its compact and cost-efficient design, Sandwich TOF-iCT has the potential to make iCT more feasible and attractive for clinical application, which, eventually, could enhance the treatment planning quality.


Assuntos
Avalanche , Terapia com Prótons , Humanos , Prótons , Radiografia , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Água
19.
Sensors (Basel) ; 24(6)2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38544110

RESUMO

Compact high-frequency arrays are of interest for clinical and preclinical applications in which a small-footprint or endoscopic device is needed to reach the target anatomy. However, the fabrication of compact arrays entails the connection of several dozens of small elements to the imaging system through a combination of flexible printed circuit boards at the array end and micro-coaxial cabling to the imaging system. The methods currently used, such as wire bonding, conductive adhesives, or a dry connection to a flexible circuit, considerably increase the array footprint. Here, we propose an interconnection method that uses vacuum-deposited metals, laser patterning, and electroplating to achieve a right-angle, compact, reliable connection between array elements and flexible-circuit traces. The array elements are thickened at the edges using patterned copper traces, which increases their cross-sectional area and facilitates the connection. We fabricated a 2.3 mm by 1.7 mm, 64-element linear array with elements at a 36 µm pitch connected to a 4 cm long flexible circuit, where the interconnect adds only 100 µm to each side of the array. Pulse-echo measurements yielded an average center frequency of 55 MHz and a -6 dB bandwidth of 41%. We measured an imaging resolution of 35 µm in the axial direction and 114 µm in the lateral direction and demonstrated the ex vivo imaging of porcine esophageal tissue and the in vivo imaging of avian embryonic vasculature.


Assuntos
Transdutores , Animais , Suínos , Desenho de Equipamento , Ultrassonografia , Imagens de Fantasmas , Impedância Elétrica
20.
Sensors (Basel) ; 24(6)2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38544238

RESUMO

The development of new medical-monitoring applications requires precise modeling of effects on the human body as well as the simulation and the emulation of realistic scenarios and conditions. The first aim of this paper is to develop realistic and adjustable 3D human-body emulation platforms that could be used for evaluating emerging microwave-based medical monitoring/sensing applications such as the detection of brain tumors, strokes, and breast cancers, as well as for capsule endoscopy studies. New phantom recipes are developed for microwave ranges for phantom molds with realistic shapes. The second aim is to validate the feasibility and reliability of using the phantoms for practical scenarios with electromagnetic simulations using tissue-layer models and biomedical antennas. The third aim is to investigate the impact of the water temperature in the phantom-cooking phase on the dielectric properties of the stabilized phantom. The evaluations show that the dielectric properties of the developed phantoms correspond closely to those of real human tissue. The error in dielectric properties varies between 0.5-8%. In the practical-scenario simulations, the differences obtained with phantoms-based simulations in S21 parameters are 0.1-13 dB. However, the differences are smaller in the frequency ranges used for medical applications.


Assuntos
Neoplasias da Mama , Micro-Ondas , Humanos , Feminino , Reprodutibilidade dos Testes , Imagens de Fantasmas , Simulação por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...